Section 6 sheet 4 Note 704-511 Obliteration of Pavement Marking - There is not a removeable non-reflective preformed tape available that is same color as concrete. Please advise what other forms of obliteration are acceptable.

DOT Response

Common acceptable methods include paint that is similar in color, shot blasting, water blasting, grinding.

Submitted: 11/2/2026 4:02:41 PM

Answered: 11/3/2026 3:21:57 PM

Referring to sheet 3 in section 20, what is the extent of the reinforcement in the concrete roadway above the sleeper slab as shown in the bottom detail?

DOT Response

Reinforcement should be provided in the roadway slabs over the sleeper slabs for the full width of the PCC, including the shoulders.

Submitted: 10/30/2026 3:58:52 PM

Answered: 11/2/2026 11:00:11 AM

Referring to sheet 13 in section 20, the rebar mats appear to be narrower than the full width of the panels. What are the widths of the rebar mats?

DOT Response

Refer to section 20 sheet 2 and the section 90 sheets for the dowel basket lengths. The reinforcement over the pipes should match the dowel basket lengths at each location, while following the details of section 20 sheet 13.

Submitted: 10/30/2026 3:55:06 PM

Answered: 11/3/2026 3:09:05 PM

Note 302-115 requires type C surface tolerance. Does this apply to SBC under asphalt pavement or sidewalk?

DOT Response

Trim base course under the proposed concrete section as specified in 302.04 C.3, "Surface Tolerance Type C." Trim base course placed below the asphalt shoulder as specified in Section 302.04 C.2, “Surface Tolerance Type B.”

For the sidewalks, the governing requirement is the subgrade tolerance of a maximum 1/2-inch deviation in 10 feet, together with the standard drawing requirement for the 4-inch base beneath the sidewalk. 

Submitted: 10/30/2026 3:52:41 PM

Answered: 11/2/2026 11:45:15 AM

Is optimized graded aggregate required for hand placed concrete pavement, for example, leave-outs, tie-ins, gores, sleeper slabs, shoulders?

DOT Response

Yes. This would apply to all 550 concrete being placed.

Submitted: 10/30/2026 3:48:45 PM

Answered: 11/2/2026 9:29:44 AM